AquaEdge with Greenspeed Water-Cooled Centrifugal Chiller with VFD
AquaEdge with Greenspeed Water-Cooled Centrifugal Chiller with VFD

AquaEdge with Greenspeed Water-Cooled Centrifugal Chiller with VFD

MOQ : 1 Unit

AquaEdge with Greenspeed Water-Cooled Centrifugal Chiller with VFD Specification

  • Dimension (L*W*H)
  • Approx. 5100mm x 2400mm x 2900mm (model dependent)
  • Place of Origin
  • India
  • Power Consumption
  • Optimized per VFD, model dependent (approx. from 500 kW and above)
  • Running Current
  • Model specific; typically 850-1500 A
  • Compressor
  • Centrifugal, single or dual stage
  • Power Supply
  • Direct to unit; integrated starter/VFD
  • Power Mode
  • Variable Speed
  • Cooling Capacity
  • 1050 kW to 10500 kW
  • Temperature Control
  • Precision Electronic Control
  • Type Of Compressor
  • Oil-free, Magnetic Bearing Centrifugal Compressor
  • Mounting
  • Floor Mounted
  • Condition
  • New
  • Air Flow Capacity
  • Not applicable (Water-cooled system)
  • Refrigerant
  • R-134a or R-513A (low GWP options available)
  • Sensible control
  • Microprocessor-based system control
  • Type
  • Water-Cooled Centrifugal Chiller with VFD
  • Cooling/Heating
  • Cooling Only
  • Capacity
  • 300-3000 TR (Ton of Refrigeration)
  • Power Source
  • Electric
  • Voltage
  • 380-480V, 3 Phase, 50/60Hz
  • Color
  • Blue/Grey
  • Weight (kg)
  • Ranges from 8000 kg to 21000 kg (varies per model)
  • Working Temperature
  • Chilled Water Outlet 4C to 15C; Condenser Water Inlet 15C to 37C
  • Fan Speed
  • Variable (depends on VFD and model)
  • Noise Level
  • Low; approximately 75 dB(A)
  • Energy Efficiency Rating
  • Up to 0.48 kW/TR IPLV
  • Remote Operated
  • Yes
  • Condenser Water Pressure Drop
  • Variable, approx. 40-80 kPa depending on configuration
  • Startup/Shutdown Auto Sequence
  • Implemented
  • Control Interface
  • Touchscreen, BACnet/Modbus connectivity
  • Lubrication System
  • Oil-free magnetic bearing - reduced maintenance
  • Application
  • Commercial AC plants, district cooling, data centers, and industrial HVAC
  • Safety Features
  • Comprehensive safety sensors for temperature, pressure, oil, and power
  • Maximum Water Flow Rate
  • Up to 1900 m3/h (model dependent)
  • Corrosion Protection
  • Optional marine waterboxes and epoxy coating available
  • Refrigerant Leak Detection
  • Integrated sensors with alarm and BMS connection
  • Heat Exchanger Material
  • High-efficiency flooded shell-and-tube (copper tubes)
  • Integrated Variable Frequency Drive (VFD)
  • Yes, for precise load matching & energy savings
 

AquaEdge with Greenspeed Water-Cooled Centrifugal Chiller with VFD Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 7 Days
 

About AquaEdge with Greenspeed Water-Cooled Centrifugal Chiller with VFD

Cooling capacity: 1055~3869 kW

Feature

Unmatched Performance

  • IPLV: 11.8
  • Full Load COP: 7.0
  • 30s swift restart

Robust & Optimized Operation

  • Refrigerant lubricated ceramic bearings
  • Balanced thrusts by back-to-back two-stage compressor design
  • 10% low load operation
  • THD <5% harmonic filter

Environmental Leadership

  • PUREtecTM application for R-1233zd(E) of GWP~1
  • Higher energy efficiency to reduce carbon emission

 



Advanced Energy Efficiency

The AquaEdge chiller's integrated variable frequency drive (VFD) and oil-free magnetic bearing centrifugal compressor enable automatic adaptation to real-time cooling loads, minimizing energy wastage. This precision drives operational costs down and yields one of the highest IPLV ratings in the market, benefiting both large-scale commercial operators and eco-conscious facilities.


Smart Control and Connectivity

With a modern touchscreen interface and BACnet/Modbus connectivity, monitoring and adjusting the chiller has never been easier. The microprocessor-based control allows for real-time remote operation via building management systems, ensuring seamless integration and intuitive system management for all major facility operations.


Durability and Low Maintenance

Built with a flooded shell-and-tube heat exchanger using copper tubes, AquaEdge is engineered for longevity and performance. The oil-free magnetic bearing system minimizes mechanical wear, resulting in lower maintenance requirements and improved reliability. Optional marine waterboxes and coatings defend against corrosion in challenging environments.

FAQ's of AquaEdge with Greenspeed Water-Cooled Centrifugal Chiller with VFD:


Q: How does the integrated variable frequency drive (VFD) in the AquaEdge chiller optimize energy savings?

A: The VFD automatically adjusts the compressor speed to match cooling demand, ensuring the chiller operates at peak efficiency under varying loads, reducing power consumption, and lowering overall operational costs.

Q: What safety features are included to protect the AquaEdge chiller during operation?

A: The chiller is equipped with comprehensive safety sensors for monitoring temperature, pressure, oil levels, and electrical supply, along with integrated refrigerant leak detectors, to prevent faults and provide early alerts through alarms and building management system connections.

Q: When is the AquaEdge chiller most effective for installation and use?

A: This chiller is ideal for installation in commercial AC plants, data centers, district cooling schemes, and industrial HVAC systems where continuous, efficient, and reliable cooling is required, especially at capacities between 1050 kW and 10500 kW.

Q: Where can the AquaEdge chiller be integrated and remotely operated?

A: The chiller can be installed in any facility with compatible chilled water requirements within its operating temperature range (outlet 4C to 15C, condenser water inlet 15C to 37C). Remote operation is possible via BMS or accessory interfaces, supporting installation flexibility.

Q: What process is involved in starting up and shutting down the chiller?

A: The AquaEdge features an automated startup and shutdown sequence, managed by precision electronic controls. This process ensures smooth transition between operating modes, reducing the potential for operator error or mechanical stress.

Q: How does the oil-free magnetic bearing system benefit the user?

A: The oil-free magnetic bearing technology virtually eliminates oil-related maintenance, reduces mechanical wear, and improves overall system reliability and efficiency, which translates to lower lifecycle costs for the user.

Q: What measures are available to protect the chiller against corrosion and harsh environments?

A: Optional marine waterboxes and epoxy coatings provide enhanced protection for the heat exchangers and other wetted components, ensuring reliable operation even in environments with high salinity or corrosive exposure.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Chillers - Heat Pumps Category

Carrier Modular Scroll Chiller

Carrier Modular Scroll Chiller

Minimum Order Quantity : 1 Unit

Place of Origin : India

Color : White/Blue

Type : Air Cooled Modular Scroll Chiller

Noise Level : Low

Dimension (L*W*H) : 2300 x 1100 x 2000 mm

AquaForce - Air Cooled Screw Chiller 30XF

AquaForce - Air Cooled Screw Chiller 30XF

Minimum Order Quantity : 1 Unit

Place of Origin : India

Color : White

Type : Air Cooled Screw Chiller

Noise Level : 69 dBA

Dimension (L*W*H) : 4826 mm x 2182 mm x 2141 mm

AquaEdge Water-Cooled Centrifugal Chiller

AquaEdge Water-Cooled Centrifugal Chiller

Minimum Order Quantity : 1 Unit

Place of Origin : India

Color : Blue / Silver

Type : WaterCooled Centrifugal Chiller

Noise Level : Low Noise Operation

Dimension (L*W*H) : varies by model (e.g. 5100x2100x2350 mm)



Back to top