X Power Carrier Xpower VRF systems
X Power Carrier Xpower VRF systems

X Power Carrier Xpower VRF systems

MOQ : 1 Unit

X Power Carrier Xpower VRF systems Specification

  • Place of Origin
  • India
  • Compressor
  • Twin-Rotary
  • Power Consumption
  • As per unit and capacity
  • Power Supply
  • 50 Hz
  • Filtration Grade
  • Standard
  • Air Flow Capacity
  • 5000 - 11000 m3/h
  • Outdoor Fan Input
  • As per model specification
  • Dimension (L*W*H)
  • 952 400 1,350 mm (varies by model)
  • Heating Capacity
  • 25.0 kW - 73.5 kW
  • Temperature Control
  • Digital / Microprocessor
  • Condition
  • New
  • Indoor Fan Input
  • As per indoor unit
  • Power Mode
  • Three Phase
  • Type Of Compressor
  • Inverter Driven
  • Cooling Capacity
  • 22.4 kW - 67.0 kW
  • Running Current
  • 16.5 A - 53.0 A (model dependent)
  • Mounting
  • Floor Standing / Outdoor Installation
  • Sensible control
  • Yes
  • Refrigerant
  • R410A
  • Type
  • VRF System
  • Cooling/Heating
  • Cooling/Heating
  • Capacity
  • 8 HP - 24 HP
  • Power Source
  • Electric
  • Voltage
  • 380-415V
  • Color
  • White
  • Weight (kg)
  • 265-335 kg (depending on capacity)
  • Working Temperature
  • -5C ~ 48C Cooling / -20C ~ 24C Heating
  • Fan Speed
  • Multiple
  • Noise Level
  • Low (as per model specification)
  • Energy Efficiency Rating
  • High
  • Remote Operated
  • Yes
  • Heat Exchanger
  • Hydrophilic Aluminum Fin
  • Protection Function
  • Overload, Phase Failure, Overheat
  • Maximum Number of Connectable Indoor Units
  • Up to 64
  • Defrost Function
  • Automatic
  • Control System
  • Centralized/Individual
  • Humidity Control
  • Yes
  • Pipe Connection Size
  • As per model (refer datasheet)
  • COP (Coefficient of Performance)
  • Up to 4.3
  • Communication Protocol
  • Modbus / BACnet compatible
  • Installation Location
  • Commercial / Residential Buildings
  • Advanced Diagnostics
  • Built-in Self-diagnosis
  • Display
  • LED / LCD (wired or wireless remote)
  • Automatic Restart
  • Yes
  • Pipe Length (total/height difference)
  • Up to 1000 m/110 m (max)
 

X Power Carrier Xpower VRF systems Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 50 Units Per Month
  • Delivery Time
  • 7 Days
 

About X Power Carrier Xpower VRF systems

Feature

  • Wide Ambient range: -15°C to 55°C in Cooling mode
  • Best in class piping : Total piping length upto 1100m
  • EVI compressor technology : Enhanced Vapor Injection (EVI) Compressor boosts cooling and heating capacities
  • IP55 Fully sealed e-box Protects from water, dust, rodents and small insects along with Inbuilt fan and PTC heater
  • Energy savings : Full DC Inverter Technology for precise speed adjustments and optimal system performance
  • Micro- channel heat exchanger : Increases the speed of temperature change due to large surface area of metal plates
  • Advanced subcooling technology :Enhances refrigerant heat transfer and reduces noise
  • Enhanced Flexibility through communication Bus smartlink : The system provides installation flexibility in the form of daisy chain, tree, circle and star connnections.
  • Sensor Backup : Virtual sensors ensure continuous operation, backing up physical sensors
  • Quadruple Backup : Quadruple backup system provides redundancy for units, fans, compressors, and sensors
  • Easy maintenance : Doctor 2.0 smart maintenance tool with Bluetooth for easy system monitoring and maintenance
  • Auto refrigerant charge Automatic refrigerant charging simplifies installation and maintenance

 



Efficient, Scalable Cooling and Heating

X Power Carrier Xpower VRF systems deliver high-precision temperature and humidity control in buildings of varying sizes. With cooling capacities between 22.4 kW and 67.0 kW, and heating capacity from 25.0 kW to 73.5 kW, they support demanding environments with low noise and consistent performance-even in extreme temperatures.


Flexible Installation and Operation

The system's modular design allows up to 64 indoor units to be connected, with flexible piping up to 1000 meters in total length and 110 meters of height difference. Floor standing or outdoor mounting options make integration easy for both commercial and residential projects.


Advanced Control and Diagnostics

Choose centralized or individual control using LED/LCD displays, wired or wireless remotes, and benefit from built-in self-diagnosis for smooth and reliable operation. Modbus and BACnet compatibility ensure seamless integration with modern building management systems.

FAQ's of X Power Carrier Xpower VRF systems:


Q: How many indoor units can be connected to the Xpower VRF system?

A: The X Power Carrier Xpower VRF system can connect up to 64 indoor units, making it highly suitable for large commercial or residential applications requiring scalable comfort solutions.

Q: What are the main benefits of using the Xpower VRF system for my building?

A: Key advantages include high energy efficiency (COP up to 4.3), advanced humidity and temperature control, automatic restart, overload and phase failure protection, low noise operations, and flexible installation options to suit diverse building requirements.

Q: Where can the Xpower VRF systems be installed?

A: These systems are designed for both commercial and residential buildings, and can be installed outdoors or as floor-standing units, offering flexibility to meet various architectural and space constraints.

Q: How does the control system work in Xpower VRF solutions?

A: The VRF system provides centralized and individual control options through digital or microprocessor technology, with user-friendly LED or LCD displays and remote access, ensuring convenient management of indoor climate and system diagnostics.

Q: What process ensures continuous operation during power failures or system faults?

A: The system is equipped with automatic restart and built-in protection functions, such as overload, phase failure, and overheat protection, as well as advanced diagnostics for prompt self-diagnosis and recovery.

Q: What is the recommended pipe connection and length for installation?

A: Pipe connection sizes vary by specific model and should be confirmed using the relevant datasheet. Generally, the VRF system supports pipe runs up to 1000 meters in total length and a height difference of up to 110 meters.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Carrier VRF X Power Category

X Power Mini VRF

X Power Mini VRF

Minimum Order Quantity : 1 Unit

Place of Origin : India

Capacity : 8 HP

Type : Mini VRF

Remote Operated : Yes

Compressor : Other, Inverter Rotary

X Power i Carrier Xpower VRF systems

X Power i Carrier Xpower VRF systems

Minimum Order Quantity : 1 Unit

Place of Origin : China

Capacity : 8 HP to 54 HP (Modular) / Up to 150% piping connection ratio

Type : VRF (Variable Refrigerant Flow) System

Remote Operated : Yes

Compressor : Other, Twin Rotary / Scroll

X Power VX Series

X Power VX Series

Minimum Order Quantity : 1 Unit

Place of Origin : India

Capacity : 1.5 Ton

Type : Split AC

Remote Operated : Yes

Compressor : Other, Rotary



Back to top